The 2020 contract is now available! Booths 1-500 will be assigned begining March, 25th. 

E2S Warning Signals

17633 Telge Road,
Building 1, Telge Industrial Estate,
Cypress,  TX  77429

United States
http://www.e2s.com
  • Booth: 1739

E2S is the world’s leading independent warning signals manufacturer with over 25 years of engineering expertise. Our worldwide approved products combine the latest technology with leading industrial design and build quality to deliver signals you can depend on.


 Products

  • D1xB2XH2
    The D1xB2XH2 is the brightest explosion proof Xenon Strobe beacon available for public mode fire alarm, ADA compliant, hearing impaired applications. The unit is UL/cUL approved for Class I Div 1, Class II Div 2, Zone 1 for gas and dust environments....

  • The D1x family from E2S is the brightest UL1971/UL1638 signal available for Class I/II Div 1 or Zone 1/20 explosion proof applications.
    The D1xB2XH2 model has a UL1971 light output of over 190 candelas with an operating current of only 1.16A and the D1xB2XH1 model achieves over 86 candelas whilst drawing only 635mA.
    The lightweight, marine grade, enclosure has been designed to create the optimal fire signal. Its innovative construction includes both conduit or surface mounting capabilities - without the need for any additional accessories. For complete flexibility an optional stainless-steel bracket enables the light to be rotated and positioned in any orientation.
    Suitable for Class I environments, including all gas groups A, B, C & D, as well as Class II. The extended operating temperature range of up to -67° to +176°F ensures the D1xB2 beacons can be employed in the most arduous of applications.
    The unique E2S automatic flash synchronization feature removes the need for additional synchronization modules. When combined with the innovative in-rush limiting electronic circuit design and low operating current, more D1xB2 visual signals can be installed per circuit – simplifying system design and reducing cost.
  • D2xC2LD2-H
    The D2xC2LD2-H is an auto-synchronizing horn & LED beacon tested to UL464 & UL1971 for public mode fire alarm, ADA compliant, hearing impaired applications. Approved for Class I Div 2, Class II Div 2, Class I Zone 2/22 as well as IECEx/ATEX Zone 2 and 22....

  • The D2x range provides high-performance signaling for hazardous and industrial locations in a compact enclosure. Globally certified by UL to: NEC Class I/II Div 2 and NEC & CEC Class I Zone 2/22 plus IECEx & ATEX Zone 2/22.
    Designed for applications requiring compliant signals to UL464 and UL1638 for public mode fire alarm installations and to UL1971 as emergency-signaling devices for the hearing impaired.
    The D2xB1LD2-H is a synchronized, supervised, hazardous location LED beacon signal with a 38.38cd output. Automatically synchronized without the need for additional modules. Industry leading low in-rush and minimal current consumption coupled with a LED life time of over 60,000 hours - the D2xB1LD2-H is the next generation of hazardous location fire signals.
    The D2xB1XH1 (19.70cd) and the D2xB1XH2 (77.72cd) satisfy applications requiring Xenon strobes. These high output visual signals also automatically synchronize without the need for additional modules, reducing overall system cost and installation time. Designed to minimize inrush and maximize the number of devices per circuit.
    For complete audio-visual warning the D2xC2 type combination unit provides the ultimate in fire signaling. With a sound output up to 116dB(A), 64 alarm tone frequencies and 4 remotely selectable stages/chanels, the alarm horn can provide safe signaling for multiple scenarios from one device. The integrated LED or Xenon beacon can be linked internally to the alarm horn minimizing cabling and installation time. The entire assembly is automatically synchronized with other D2xC2 units on the same circuit without the need for synchronization modules. The D2xS1 alarm horn is also available for applications requiring only
    audible signaling.
    The marine grade aluminum enclosure with an ingress protection of IP66/Type 4, 4X is suitable for the
    harshest of environments. The range is approved for use in both gas and dust atmospheres.
  • D1xC1X05R
    D1xC1X05R Radial Alarm Horn & Xenon Strobe 115dB(A) horn & 5 Joule Xenon - high output alarm horn sounder with omni-directional radial horn combined with a 500,000cd Xenon strobe beacon. Class I & II Division 1, Zone 1 & 20 - approved for fire alarm use....

  • The D1x combined signals - audible and visual warning from one device.
    The Xenon strobe beacons are combined with alarm horn sounders either employing a traditional flare horn design, or the compact radial horn design which distributes sound omni-directionally and enables the beacon to be oriented optimally in any direction.
    Strobe versions include 5 or 10 Joules with candela outputs of up to 1,000,000cd. Available in seven colors with a UV stable PC, field replaceable, filter. The flare version alarm horn sounders are available in sound pressure levels of up to 117 and 125dB(A).
    The D1x combined signals in 24Vdc operating voltage are approved for audible public mode and visual private mode fire alarm use.
    A threaded flame path enable quick installation and simplifies maintenance inspection whilst the innovative internal arrangement maximises wiring space. The ratchet adjustable mounting bracket allows the device to be positioned for maximum effectiveness.

    The powerful D1x alarm horn sounders are available with traditional flare horn design or the compact radial horn design which distributes the warning signal omni-directionally.
    All versions offer 64 different first stage/channel alarm sounds which can be selected via an internal switch. Each tone can be remotely triggered e.g. via an external relay, to change to a second, third or fourth stage/channel alarm sound.
    The D1xS1 alarm horn variants, in 24Vdc operating voltage, are approved for public mode fire alarm use.
    The D1x PA loudspeaker driver and flare horn is available in 15 or 25W versions. Input options include 8 or 16 ohm low impedance and 70V line transformer.
    The 70V line transformer units feature multiple tappings for each version of the loudspeaker. Field replaceable flare - driver employs standard 1 3/8” -18 male thread coupling.

Visit the Exhibitor Resources Page to:

  • Read OTC Rules and Regulations
  • Manage/Designate EAC's
  • Submit contractor orders: Carpet, Decor, Electrical, Shipping, Audio Visual, Etc.
  • See a list of deadlines
  • View the Target Move-in maps

Please contact otc.events@otcnet.org for questions.
For technical assistance or upgrade questions please contact: support.