UT99 AG, founded 50 years ago, designs and manufactures best-in-class “smart filtration" oil mist separation systems. Many world-wide leading combustion engine and turbine manufacturers rely on the superior and unrivalled UT99 oil mist separation technology for open (OCV) as well as closed (CCV) crankcase ventilation and for lube oil tank ventilation (OTV).


 Press Releases

  • The Swiss company UT99 Ltd. is participating for the first time at the OTC exhibition in Houston. The firm is presenting its highly efficient “smart filtration” oil mist separators at booth 7429. UT99 provides separation efficiency of 99.9% and thus is well below the technical guidelines for air pollution control. The main benefits when using UT99 "smart filtration"oil mist separation technology are

    + less costs and higher engine reliabilty

    + improved health and safety

    + increased efficiency

    UT99 is a supplier to several world-wide leading combustion engine and turbine manufacturers, shipyards as well as to the on- and off-shore industry. Recently, the company has presented the world’s first oil mist eliminator for crankcase (combustion engine) and lube oil tank (gas and steam turbines) ventilation with classification approval by GL. In addition, RINA type approval was achieved for oil mist eliminators operating on diesel, gas and DF engines. The approval for the oil mist eliminator type UPF-844-MZ was confirmed and emphasizes the company’s focus on ships and offshore applications. Meanwhile, a large number of cruise ships, mega-yachts as well as several LNG carriers but also offshore platforms have been successfully equipped with UT99 oil mist separators. Besides environmental and efficiency related benefits, UT99 oil mist separators also substantially increase the safety and comfort aboard a ship or oil-rig.

     

    UT99 has its latest innovations on display; the UPF-SauKuL and UPF-CCV-450 for the ventilation of small and medium sized crankcases, eg. combustion engines up to 500 kW respectively 3MW as well as housings of auxiliary equipment (tanks, gears, clutches). Visit UT99 at OTC in order to get first-hand information on oil mist separation, trends and developments.
  • The company UT99 AG is one of the pioneers in the development and manufacture of highly efficient oil mist separators for crankcase ventilation of combustion engines and for lubricating oil tank vent for turbines. The oil mist separators are designed for use in power generation, chp, off-highway, marine and off-shore applications with all kinds of fuel.

    "The world's first class admission of Germanischer Lloyd and RINA for a secure oil mist separator is the systematic continuation of our philosophy," explains Remo Oppliger, CEO of UT99 AG.

    Environmental and safety requirements are getting higher in the marine and offshore sectors in the future. Customers are demanding products that meet the specific requirements in maritime and offshore operations. With the GL and RINA approval UT99 AG has proven that their products fulfill highest demands on safety and reliability. Furthermore, the discharge of oil emissions from the crankcase ventilation and from the lubricating oil tank ventilation, respectively, is almost completely eliminated. Depending on the model residual oil amounts below 1 mg/m³ in the exhaust air (e.g. blow-by) will be ensured.

    The portfolio of oil mist separators with GL and RINA approval includes volume flows (e.g. blow-by) up to 1050 m³/h and can be used on internal combustion engines up to 100 MW and all available sizes of gas and steam turbines.

    The modular design allows a wide variety of options while reducing the cost and variety of components and spare parts.

    The application areas include open and closed crankcase ventilation in internal combustion engines as well as the lubricating oil tank vent for turbines. The electronic under pressure control in connection with electrically driven fan ensure a constant adjustable negative pressure under all operating conditions. The ATEX approval of the device allows the use even in hazardous areas.

    The customers of the UT99 AG are leading motor and turbine manufacturers, plant manufacturer and shipyards, including amongst others 2G Energy AG, Alstom Power, Caterpillar Energy Solutions GmbH, Liebherr Components, MAN Energy Solutions SE, Meyer Werft GmbH, MTU Friedrichshafen GmbH, Bergen Engines AS, Siemens AG, Siemens Engines S.A.U. and TEDOM SCHNELL GmbH.

    https://www.ut99.com/en


 Products

  • Oil Mist Separators of UPF-CCV and UPF-OCV Series
    Blow-by filters for open and closed crankcase ventilation of combustion engines as well as lube oil tank ventilation...

  • Oil Mist Separators of UPF-CCV Series: These blow-by filters are used for closed crankcase ventilation of combustion engines. Less costs, improved health and safety and greater environmental protection – there are many good reasons to use closed crankcase ventilation. Years of experience and designated references are proof of the reliable and flawless interaction of the components, so that your engines and customers benefit permanently from all positive aspects.

    UPF-CCV specifications

    • Coalescence filter

    • Oil mist separation: 99.9 %

    • Residual oil content after filtration: < 1 mg/m³, up to 0.1 mg/m³ if required

    • Filtration: up to 0.1 μm droplet size

    • Pressure loss: < 20 mbar, up to 8 mbar if required

    • ATEX certification: optional

    • Germanischer Lloyd (GL) and RINA type approval: optional

    • Maintenance-friendly, filter change intervals up to 16,000 hours; depending on the design, also up to 32,000 hours

    Oil Mist Separators of UPF-OCV Series: Blow-by filters for open crankcase ventilation. Especially for engines with a power of up to 100 megawatts our oil mist separators ensure top separation performance and functional safety – thus, they can be used even for critical applications, such as a potentially explosive atmosphere. With a residual oil quantity of less than 5 mg/m³, the statutory limit values of the TA Luft are significantly undercut. When required, we provide all models in an ATEX certified design.

    UPF-OCV specifications

    Coalescence filter

    • Oil mist separation: 99.5 %

    • Residual oil content after filtration: < 5 mg/m³

    • Limit values of TA Luft are undercut

    • Filtration: up to 0.1 μm droplet size

    • ATEX certification: optional

    • Germanischer Lloyd (GL) and RINA type approval: optional

    • Maintenance-friendly, filter change intervals up to 24,000 hours; depending on the design, also up to 32,000 hours